Skip to main content

Table 9 Test results of specific distortion types under the CSIQ database

From: Explicit-implicit dual stream network for image quality assessment

Algorithm JP2K JPEG Noise Blur FF All
PSNR 0.941 0.901 0.943 0.936 0.915 0.928
SSIM 0.962 0.956 0.912 0.965 0.937 0.935
VIF 0.967 0.970 0.957 0.975 0.963 0.972
BIQI 0.975 0.962 0.954 0.968 0.936 0.927
DIIVINE 0.831 0.800 0.866 0.872 0.891 0.864
BLIINDS-II 0.895 0.900 0.801 0.892 0.868 0.892
BRISQUE 0.867 0.909 0.925 0.903 0.859 0.916
SSEQ 0.977 0.975 0.983 0.961 0.904 0.955
EI-IQA 0.954 0.938 0.969 0.911 0.957 0.936