Skip to main content

Table 3 Comparison of experimental failure causes

From: Experimental study on three-dimensional shape mapping of complex furniture

Objects

Measuring times

Operational error

Aroma bottle

1

The first attempt was affected mainly by the dual-camera sensor

Unpainted carved panels

4

1. The cabinet used to keep the object stable was not good. Objects can change position easily.

2. The measured object height is not appropriate; the edge is difficult to clearly sweep to.

3. The surface on which the object to be measured is placed is too large, and this affects the scanning of the partial scan angle.

Painted carved panels

2

Support area is greater than the measured object, which leads to too many useless data points.

Carved round stool

3

1. Wrong position, wrong height, and the support surface is too large.

2. The angle of the impact signal was not taken into account.