From: Condensed anisotropic diffusion for speckle reducton and enhancement in ultrasonography
Method | Simulated B mode image | Field II simulated foetus image | Real US image | |||||
---|---|---|---|---|---|---|---|---|
 |  SNR |  MSE |  FOM |  SNR |  MSE |  FOM |  SNR |  FOM |
Noisy |  15.867 |  100.56 |  0.0969 |  25.538 |  121.69 |  0.0907 |  23.718 |  0.0976 |
PM |  19.486 |  88.64 |  0.1092 |  28.937 |  84.85 |  0.1762 |  25.645 |  0.1792 |
AWMF |  20.097 |  92.63 |  0.2206 |  29.427 |  91.02 |  0.2009 |  27.097 |  0.2461 |
SRAD |  24.468 |  51.84 |  0.3325 |  32.618 |  58.69 |  0.3786 |  29.678 |  0.3357 |
NCD |  28.093 |  76.92 |  0.3768 |  34.936 |  78.09 |  0.3868 |  31.493 |  0.3668 |
MBAD |  32.386 |  58.89 |  0.3976 |  35.227 |  62.56 |  0.3902 |  32.386 |  0.4462 |
LPND |  36.753 |  45.63 |  0.4186 |  38. 538 |  58.63 |  0.4409 |  37.789 |  0.4798 |
CAD |  41.923 |  16.246 |  0.5032 |  44.419 |  19.56 |  0.5156 |  44.087 |  0.5332 |